baSeq
baSeq docs › CHANGE-seq

CHANGE-seq

Everywhere a guide and its nuclease can cut genomic DNA, measured in a tube rather than in a cell: the sequence's own say in where a nuclease cuts, before chromatin has any, and which of those places to go looking for in cells.

What the assay does

Purified genomic DNA is cut into fragments of about four hundred bases, and those fragments are circularised; everything still linear is then destroyed by exonucleases, so what is left is a library of DNA circles and nothing else. The nuclease and its guide are added to that. A circle the nuclease cuts becomes linear, and only a linear fragment can take a sequencing adapter, so the library that comes out is made of exactly the circles that were cut. Each read pair reads outwards from the two faces of one cut.

CHANGE-seq (Lazzarotto et al., Nature Biotechnology 2020) is the higher-throughput rebuild of CIRCLE-seq, using a tagmentation step in place of shearing, and it needs a fraction of the input DNA. Across 110 guides at thirteen therapeutically relevant sites it found 202,043 cleavage sites, between 19 and 61,415 for a single guide.

Why a tube rather than a cell, and what follows from it

This is the only assay in baSeq whose nuclease never met a cell, and almost everything about reading it follows from that.

In a cell a site has to be accessible before the nuclease can reach it, the nuclease is present for a few hours, and a cut that is made is usually repaired without leaving a trace. In a tube there is none of that: the DNA is naked, the enzyme is in excess overnight, and every circle it cuts is read. So every site the sequence allows is cut, the lists are long, and a read count is an intrinsic activity rather than an editing rate.

That makes the list a superset rather than a prediction. The method's own authors took 648 of these sites to deep amplicon sequencing in cells: 278 of them, 42.9%, showed real editing. Of the sites CHANGE-seq and GUIDE-seq both found, 98.3% were real; of the sites CHANGE-seq found and GUIDE-seq did not, 84 of 427 were real cellular off-targets that the cell-based assay had missed. So the in-vitro assay is the more sensitive of the two, and most of what it finds a cell still never cuts.

What explains the gap is chromatin. Cellular off-target activity is between two and four times more likely in open chromatin, active promoters, enhancers and strongly transcribed regions, and is enriched at H3K4me3 and H3K27ac but not at H3K27me3 or H3K9me3. None of that is visible to an assay with no chromatin in it, which is why baSeq's In Cells step asks how far down the in-vitro ranking to look rather than treating the list as a set of predictions to be scored.

Reads, not molecules

There is no molecular index anywhere in this protocol, so every count in a CHANGE-seq analysis is a count of reads: a circle amplified a thousand times counts a thousand times, and nothing in the data can correct it. baSeq says reads on every axis for that reason. It matters most when a CHANGE-seq list is put beside a GUIDE-seq one, whose counts are molecules.

The control, and what baSeq does with it

Each treated library has a matched no-nuclease control: the same circularised DNA, no enzyme. It catches the places the library breaks on its own, which are properties of the DNA rather than of the guide and which land in the same places either way. The reference pipeline requires a control and then reports it without using it, calling a site on a read count alone; the enrichment test CIRCLE-seq published for the same purpose is still in that code, switched off. baSeq offers both, says which it applied, and reports the other beside it, so a site's read count and its excess over its own control can be read together.

Which sites are worth confirming

The useful answer here is published and measured, so baSeq uses it rather than a rule of its own. The validation experiment sorted its 648 sites into four classes on two features, how far the site is from the guide and how strong it is, and each class came back with its own rate: 42% for one to three mismatches at a medium or high read count, 38.6% for four mismatches at a high read count, 15.7% for one to three mismatches at a low read count, and 3.5% for four to six mismatches. Two features together carry a twelvefold spread in how likely a site is to be real, and either one alone does not. Those classes order baSeq's confirmation panel and, summed, give it an expected return. Where the published description says high, medium and low read counts, it gives no numbers, so baSeq cuts them at a tenth and a hundredth of the guide's own site and says so wherever it reports a rate.

What you upload

One library per sample. Either a paired BAM of the reads, and baSeq calls the cleavage sites itself, or a table of sites somebody's pipeline already called, as the CHANGE-seq or CIRCLE-seq pipeline leaves it (identified_matched.txt) or the same content as a BED or CSV. baSeq reads both of the formats that pipeline writes, including the short one that carries each site's control read count beside it. Upload the no-nuclease control library too where you have it: it holds no cleavage site, which is what it is for, and baSeq keeps it for its sequencing depth, which is what decides how much a site has to hold before it can be called above the control. A sheet naming each library's guide, nuclease and DNA input is taken if you have one, as are a GTF and a genome file. If you also have an in-cell site list for the same guides, from GUIDE-seq, UNCOVERseq or an amplicon panel, upload it with a name that says what it is and the In Cells step will compare the two.

Why a BAM tells you more than a table. A table of called sites holds the sites that passed its pipeline's own cutoff and nothing else, so three things are simply not in it: how deeply the library was sequenced, what share of its reads sit at a cleavage site at all, and the control's reads away from those sites. From the reads, all three are measured — and the control's depth is measured rather than assumed to match. A fourth measurement comes with them that no site list can give: the share of read pairs whose two ends sit on one base. A cut circle is read outward from both faces of the cut, so its two reads begin together; a fragment that was merely sheared has its ends wherever it broke. That share is how much of your library is the assay working.

Chromatin, if you have it. Upload an accessibility or histone track with the libraries — a bedGraph, a bigWig, or a peak file — and baSeq measures it at every cleavage site and asks whether the sites a cell cut sit in more open chromatin than the sites it did not. That is the published explanation for why most of what a tube cuts a cell never cuts: cellular off-target activity is two- to fourfold enriched in open chromatin, active promoters and enhancers. The comparison is reported inside bands of cleavage strength as well as overall, because a confirmed site also tends to be cut more readily, and only the comparison at one strength is a statement about chromatin. Chromatin filters nothing and changes no site's class: it is the last thing the confirmation panel sorts on, so it settles two sites that are otherwise the same candidate and never outranks the published classes or the read count. Name a peak file so it says what it is (narrowPeak, or a name with atac, dnase or a histone mark in it), or upload a bedGraph: a peak file holds a chromosome, a start and an end like a site table does, and an unrecognisable one is read as sites. baSeq claims nothing about DNA methylation, which the method paper does not examine.

Raw FASTQ can go straight onto the analysis: baSeq aligns it (see FASTQ files) and the cleavage sites are called from the BAMs it makes. The alignment is this assay's own in two ways. It is end to end, because a CHANGE-seq read begins at the cut face and is genomic from its first base — there is no adapter remnant to clip, as there is in GUIDE-seq — and the 5' end is the whole measurement, so an alignment free to trim it is the wrong one. And the pair is aligned in the orientation a cut circle really has, with the mates pointing away from each other, which most aligners do not expect by default. Duplicates are marked and never removed: every molecule cut at one site aligns identically, so removing them would collapse every site to a single read.

The reads must be paired. A single-end file is turned away with the reason: the published pipeline joins the reverse complement of one mate to the other and aligns the result as one read, which puts the cut in the middle of each alignment instead of at its start, and reading such a file as ordinary alignments would place every site a read length from the truth.

Was it sequenced deeply enough?

Every other check can pass while a run is still showing only the strong half of what it cut, so baSeq draws each library a depth curve: its own reads re-dealt over its own sites at a series of depths, and the sites that survive at each. A curve still climbing at its right-hand end means more sequencing would have found more sites. It says what a shallower run would have found and cannot say what a deeper one would — no site absent from these reads can appear in a subsample of them — and baSeq says so beside the curve rather than letting the flattening at the end be read as a promise.

Where you have replicates, two more things come out of them. Their agreement is scored the way ENCODE scores replicate peak calls (the irreproducible discovery rate), which asks how far down the two rankings the pair goes on agreeing — a question a correlation over the sites they already share cannot answer. And the spread between them measures how much more the counts vary than sampling alone explains, which in an assay with no molecular index is the PCR. That number never changes which sites are called: the test is simply run a second time at it, beside the call, so you can see which calls would not survive it.

What it does not tell you

It does not tell you that anything was edited. A site here is a site the nuclease can cut when nothing is in the way, and most such sites are never cut in a cell. It also cannot rank a guide's sites by how much editing they will cause, only by how readily the sequence can be cut, and the two differ wherever chromatin differs. The depth that baSeq recommends for each amplicon of a confirmation panel is a lower bound for the same reason: a cell is less permissive than a tube, so a negative result at that depth is not evidence that nothing happened.

Step reference

StepStageWhat it doesYou getKey inputs
Data UploadSetupReads one library per sample: a paired BAM of the reads, whose cleavage sites baSeq calls itself, or a table of sites the CHANGE-seq pipeline already called, in either of the two formats it writes, keeping each site's matched no-nuclease control read count. Finds the genome build, places every guide in every site's window, annotates the genes, works out how readily each site was cut as a share of its own guide's intended site, and sorts the sites into the published classes. An accessibility or histone track uploaded beside them is measured at every site, as context for which of them a cell is likely to cut.What each library sequenced, the most readily cut sites with their bases against the guide, how far the sites are from it, and how many fall in each published class.One table per library. A sheet naming each library's guide, nuclease and DNA input, a GTF, a genome file and an in-cell site list are taken if uploaded.
Library QualityQCWhether each library could have answered the question: the sites it found, what stands above its own control, its guide's own site, the specificity ratio, the DNA that went into the reaction, and the floor its control's depth puts under a read count. What a table of called sites cannot answer is left blank rather than computed from the sites alone.Each measure library by library, the ones to look at flagged, the DNA against the line below which a rare cut cannot be seen, and each library's detection floor.None.
Cleavage SitesAnalysisEvery cleavage site with its bases set against the guide that explains it, one panel per guide, the reads beside each row. The sites that do not stand above their control are one click away rather than hidden.One panel per guide: that guide, then its sites beneath it with mismatches in colour and the reads beside each; the most readily cut sites whatever their guide; and how concentrated the cleavage is.Which sites, their order, how many per guide, the libraries, and the mitochondrial sites.
Cleavage ActivityAnalysisHow readily each site was cut, as a share of its own guide's intended site, and how a guide's off-target cleavage is spread over its sites. Two guides with three thousand sites each are not the same risk if one keeps nine tenths of its off-target cleavage in eleven sites and the other spreads it over nine hundred.The spread of activity per guide, how few sites carry most of the cleavage, the dynamic range, and which PAMs the sites carry.Group by guide or library, whether to keep the intended site, the libraries and the mitochondrial sites.
Mismatch PatternsAnalysisWhere along the guide a mismatch is tolerated and which substitutions, with the published findings beside them: the most telling positions are the eleventh, tenth and second, and the most tolerated mismatch is a G in the guide against an A in the site.Mismatches per position of the protospacer, a substitution matrix, the sites' sequence logo, and how many sites only a gapped alignment places at all.Count each site once or by its reads. The sites, the libraries and the mitochondrial sites.
Guide SpecificityAnalysisHow specific each guide was. The centre of it is the specificity ratio as this method defines it, the share of a guide's reads that sit at its intended site, which the paper validated as a way of choosing between guides rather than of judging any one site.Each guide's specificity ratio side by side, its site count, its strongest off-target site, how concentrated its off-target cleavage is, and its sites by published class.The sites, the libraries and the mitochondrial sites.
Site AnnotationAnalysisWhere in the genome the sites landed: the nearest gene, how far its start is, and which part of the gene the site sits in. A site in a coding exon is the one to look at first, whatever its strength, because a cut there changes a protein.The sites across the genome, what they sit in, the ones in coding sequence named with their genes, and how they are spread over the chromosomes.Count sites or reads. The sites, the libraries and the mitochondrial sites.
Predicted vs DetectedAnalysisSearches the whole genome for every sequence within a few mismatches of each guide with a PAM the nuclease accepts, and lays that list beside the sites actually cut. In a tube there is no chromatin to excuse a predicted site that was not cut, which makes this comparison a sharper one than it is for a cell-based assay.What the prediction found and missed, how many places the genome holds at each mismatch count, how many of them were cut, and the cut sites no prediction reached.The genome build, the mismatches searched for and which PAMs.
ReproducibilityAnalysisHow well the replicates of a library agree. The agreement in this assay is genuinely high, the method's own technical replicates reaching an R squared above 0.9, so replicates that disagree are a problem with the run rather than a finding.Each pair of replicates against each other on the sites they share, how many sites one library alone holds and how strong those are, and the overlap across every library.A replicate group or all of them. The libraries and the mitochondrial sites.
In CellsAnalysisWhat a cell actually does at these sites, against an in-cell site list uploaded beside the libraries. The question is not whether the two lists agree, since a tube cuts far more places than a cell does, but how far down this list you must look to hold everything a cell edits, and which in-cell sites this list missed.The curve of in-cell sites held against the depth of in-vitro list taken, the depths that recover half, nine tenths and all of them, where the confirmed sites sit in the ranking, what separates them from the rest, and every in-cell site this list does not hold.How to order the in-vitro list, how close two assays' calls must be to be one cut, the libraries and the mitochondrial sites.
Confirmation PanelAnalysisThe panel to order: which sites to go looking for in cells, in what order, the amplicon window either side of each cut, and the shallowest depth worth ordering. The order is the published classes', whose measured rates also give the panel its expected return.What is on the panel by tier and by class, how many of it are likely to be real in cells, the depth each site needs, the panel in order, and a CSV a primer design tool can take.Which tiers to include, how many sites at most, the amplicon reach, the libraries and the mitochondrial sites.
Across ConditionsAnalysisWhether what was cut in one group of libraries holds in another: one nuclease against another, one DNA source against another, a wild-type enzyme against a high-fidelity one. Says when the two groups carry different guides, and refuses when they share too few sites for the comparison to mean anything.The sites each group holds and those they share, a test per site, and how many sites are a presence or absence rather than a ratio.The column to compare and its two values, and the mitochondrial sites.

Every kind of analysis baSeq runs: baseq.bio/analyses